I
did take a few other exceptions to this specification. For example, a PVC corporation stop
and nozzle assembly is called for. As far as Im aware, the corp stops available
incorporate a metal safety cable attached to a metal valve (usually bronze, since there is
no chemical contact), to insure that the nozzle is safely retained should a blow-out
occur. PVC is not that strong a material, so it is usually not used. A bit of fume
corrosion to a bronze valve is an acceptable trade-off. Another example of an exception
would be that a teflon-on-teflon pump head is called for, even though the plumbing is PVC.
Given teflons notorious reputation for cold flow, teflon-on teflon is just too
slippery to make a good check valve seal. I went with a PVC pump head with teflon seal
rings and a teflon diaphragm. Any other exceptions I made were small, based on actually
available products, or done to maintain system integrity so that the whole package
"hangs" together.
The Touchscreen will display its two 4-20 mA inputs,
the
4-20 mA output to the pump, the Digi-Pulse feedback signal to confirm
actual pump strokes, chemical flow in ml/min and total mls since last reset (Please
specify if youd like other units, like gallons per hour), and whether there is a
no-flow or low level condition. If you have any other ideas,
please let us know.
Generally, layout drawings and wiring diagrams are made
available after a contract is awarded. Manufacturers literature for non-customized
components is of course available. Please let me know what youd like us to provide.
Thanks for the opportunity to bid on this please call if youve any questions.
Tim